[File] DescText = "This is an EDS file created by Gemue/Omron"; CreateDate = 16-05-2008; CreateTime = 14:31:00; ModDate = 16-05-2008; ModTime = 14:31:00; Revision = 1.0; [Device] VendCode = 0x365; $ Vendor Code VendName = "Omron/GEMUE Apparatebau GmbH & Co. KG"; ProdType = 0x0; $ Product Type ProdTypeStr = "Generic Device"; ProdCode =4220; $ Product Code MajRev = 0x01; $ Major Rev MinRev = 0x01; $ Minor Rev ProdName = "4221/4222DN combi switch box"; Catalog = ""; [IO_Info] Default = 0x04; $ Default I/O Information Entry = COS PollInfo = 0x0f, 1, 1; StrobeInfo = 0x0f, 1, 0; COSInfo = 0x0f, 1, 1; CyclicInfo = 0x0f, 1, 1; Input1= 1, $ The size in bytes that this connection produces. 1 byte 0, $ All bits of this connection are significant. 0x04, $ Polled, COS and Cyclic I/O; Strobe device. "Input1", $ Name of Connection. 6, $ Path length. 20 04 24 66 30 03, $ Path to I/O Production Assembly. "Bit0:State Valve1 Bit1:State Valve2 Bit2:Mode Bit3:Position Close Bit4:Position Open Bit5:Sensor Error Bit6:Programming Error Bit7: Traveltime Error"; Output1= 1, $ The size in bytes that this connection consumes. 3, $ Only the least 3 significant bits of this 0x04, $ Polled, COS and Cyclic I/O; Strobe device. "Output1", $ Name of Connection. 6, $ Path length. 20 04 24 65 30 03, $ Path to I/O Consume Assembly. "Bit0:activate Valve1 Bit1:activate Valve2 Bit2-Bit6 not used Bit7:Reset Traveltime Error"; [ParamClass] MaxInst = 18; $ Number of Instances of the Parameter Class configurable 1 monitoring Descriptor = 9; $ Stub param instances in eeprom. CfgAssembly = 0; $ no Configuration Assembly [Params] Param1= 0, $ reserved for the future 6, $ Link Path size "20 0F 24 01 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type -16 Bit 2, $ Data size 2 Byte "Valve Position", $ Parameter Name "%", $ Units string "Position of the programmed valve in percentage value", $ Help string 0,100,0, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param2 = 0, 6, $ Link Path size "20 0F 24 02 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "AD-Value real", $ Parameter Name "", "The real AD-value of the position.", 0,1023,1, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param3 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 03 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0010, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, No Monitor Parameter, No extended precision scaling 0xC7, $ Data Type - Unsigned integer 16 Bit 2, $ Data size 2 Byte "Operating Time", $ Parameter Name "", $ Units string "Shows the operating hours ", $ Help string 0,65535,0, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param4 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 04 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0020, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links,No read only, Monitor Parameter, No extended precision scaling 0xC6, $ Data Type - Unsigned integer 16 Bit 1, $ Data size 2 Byte "Threshold Close", $ Parameter Name "%", $ Units string "A valve position in the range 0 to this value will be indicated as valve closed.", $ Help string 3,97,3, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param5 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 05 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0020, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links,No read only, Monitor Parameter, No extended precision scaling 0xC6, $ Data Type - Unsigned integer 16 Bit 1, $ Data size 2 Byte "Threshold Open", $ Parameter Name "%", $ Units string "A valve position in the range 100 to (100-this value) will be indicated as valve open. ", $ Help string 3,97,3, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param6 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 06 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0020, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links,No read only, Monitor Parameter, No extended precision scaling 0xC6, $ Data Type - Unsigned integer 8 Bit 1, $ Data size 1 Byte "Hysteresis Close", $ Parameter Name "", $ Units string "Acts as hysteresis at Threshold Close.", $ Help string 1,5,5, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param7 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 07 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0020, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links,No read only, Monitor Parameter, No extended precision scaling 0xC6, $ Data Type - Unsigned integer 8 Bit 1, $ Data size 1 Byte "Hysteresis Open", $ Parameter Name "", $ Units string "Acts as hysteresis at Threshold Open.", $ Help string 1,5,5, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param8 = 0, 6, $ Link Path size "20 0F 24 08 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0034, $ Bit0 - Bit6: No support for settable path, No Enumeration String, scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Close Time", $ Parameter Name "ms", "Valid detected time of the last movement from open to close.", 0,10000,0, $ Min, Max, and Default values 100,1,1,0, $ not used 0,0,0,0,0; Param9 = 0, 6, $ Link Path size "20 0F 24 09 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0034, $ Bit0 - Bit6: No support for settable path, No Enumeration String, scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Open Time", $ Parameter Name "ms", "Valid detected time of the last movement from close to open.", 0,10000,0, $ Min, Max, and Default values 100,1,1,0, $ not used 0,0,0,0,0; Param10 = 0, 6, $ Link Path size "20 0F 24 0A 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0020, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links,No read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Set Close Time", $ Parameter Name "", "Maximum allowed time for movement open to close before activating an Error.", 0,10000,100, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param11 = 0, 6, $ Link Path size "20 0F 24 0B 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0020, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links,No read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Set Open Time", $ Parameter Name "", "Maximum allowed time for movement close to open before activating an Error.", 0,10000,100, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param12 = 0, 6, $ Link Path size "20 0F 24 0C 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC8, $ Data Type 32 Bit 4, $ Data size 4 Byte "Valve Cycles", $ Parameter Name "", "Counts every valid full cycle of the valve (Open-Close-open or Close-Open-Close).", 0,4294967295,0, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param13 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 0D 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0002, $ Bit0 - Bit6: No support for settable path, Enumeration String, No scaling, No scaling links,No read only,No Monitor Parameter, No extended precision scaling 0xC6, $ Data Type -unsigned short 8 Bit 1, $ Data size 1 Byte "Programming Command", $ Parameter Name "", $ Units string "0=Programming Off, 1=starts automatic Programming, 2=starts manual Programming", $ Help string 0,2,0, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param14 = 0, 6, $ Link Path size "20 0F 24 0E 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Programming counter", $ Parameter Name "", "Counts how often the Node was in Programming Mode ", 0,65535,0, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param15 = 0, 6, $ Link Path size "20 0F 24 0F 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Powerfail counter", $ Parameter Name "", "Counts how often the Node was switched off. ", 0,65535,0, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param16 = 0, $ reserved for the future 6, $ Link Path size "20 0F 24 10 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0002, $ Bit0 - Bit6: No support for settable path, Enumeration String, No scaling, No scaling links,No read only,No Monitor Parameter, No extended precision scaling 0xD1, $ Data Type -unsigned integer 8 Bit 1, $ Data size 1 Byte "Bus Off State", $ Parameter Name "", $ Units string "State of the Valves in Bus Off State ", $ Help string 0,2,0, $ Min, Max, and Default values 0,0,0,0, $ Scaling Multiplier,Scaling Divider,Scaling Base,Scaling Offset all not used 0,0,0,0,0; $ Multiplier Link, Divider Link, Base Link, Offset Link, Decimal Precision all not used Definitions see Vol.2 Kap. 4-3 ff Param17 = 0, 6, $ Link Path size "20 0F 24 11 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Stroke", $ Parameter Name "mm", "Returns the value of the programmed stroke depending of the actuator type in 0.1mm (linear) or 0.1° (quarter turn).", 0,1000,0, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; Param18 = 0, 6, $ Link Path size "20 0F 24 12 30 01", $ Link Path "" means Link Path same as Parameter Number 0x0030, $ Bit0 - Bit6: No support for settable path, No Enumeration String, No scaling, No scaling links, read only, Monitor Parameter, No extended precision scaling 0xC7, $ Data Type 16 Bit 2, $ Data size 2 Byte "Min. Stroke", $ Parameter Name "", "Shows the minimum valid Stroke in 0.1mm (linear) or 0.1° (quarter turn).", 0,1000,0, $ Min, Max, and Default values 0,0,0,0, $ not used 0,0,0,0,0; [Groups] Group1=" Configuration",10,4,5,6,7,8,9,10,11,13,16; Group2=" Counter",4,3,12,14,15; Group3="Position",4,1,2,17,18; [EnumPar] Param13="Off","Auto","Manual"; Param16="Valve 1","Valve 2","Not Used","Not Used","Not Used","Not Used","Not Used","Not Used";