What Power Supply Should Be Used For ES2-THB Temperature/Humidity Sensors And ES2-HB Humidity Sensors? A 24-VDC power supply with a maximum ripple voltage of 2% p-p.
See whether the 24 VDC Output Power Supply Unit can be used for your application. ES2-THB and ES2-HB consume less than 10 mA of current. Select a Power Supply Unit with sufficient capacity for the number of Sensors connected. Example:
S8VS-01524 Switch Mode Power Supplies (Input: 100 to 240 VAC, Output: 24 VDC, 0.65 A) S82K-00324 Switch Mode Power Supplies (Input: 100 to 240 VAC, Output: 24 VDC, 0.13 A) Link: |
Comments | ||
|