F3G-C Error Codes - CSL

Error Code Error Description Description Action
21 Reference target Reference target statistics error, variation too high Check alignment of target / Return for Repair 
22 Reference target Reference target averaged value distance measurement too high Check alignment of target / Return for Repair 
23 Reference target Reference target - echo amplitude too small Check alignment of target / Return for Repair 
24 Reference target Reference target - echo amplitude too high Check alignment of target / Return for Repair 
25 Reference target Reference target- values occasionaly out of range Check for contamination / check alignment of target / Return for Repair 
26 Reference target Internal laser power measurement occasional out of limits  Check reference target / Return for Repair 
27 Reference target Internal laser power measurement too small  Check contamination / check alignment of target / Return for Repair 
28 Reference target Internal laser power measurement too large  Check ailgnment of target / Return for Repair 
2A Reference target Reference target: distance too high  Check alignment / return for Repair 
2B Reference target Reference target- echo amplitude too high  Check alignment / return for Repair 
2C Reference target Reference target- distance too small  Check alignment / return for Repair 
2D Reference target Reference target- echo amplitude too low  Check alignment / return for Repair 
2F Reference target In Eeprom memorized reference target data defect  Return for repair 
31 Trigger Rotating frequency too high  Return for repair 
32 Trigger Rotating frequency too low  Check whether head is blocked / Return for Repair 
33 Trigger Internal trigger signal missing  Return for repair 
34 Trigger Internal trigger signal faulty  Return for repair 
35 Trigger Internal synchronisation channel 1/2 not OK  Return for repair 
41 Comparison Fault in comparison channel 1/2 in distance or echo amplitude  Return for repair 
51 Relay Fault in relay monitoring  Return for repair 
61 System Fault on self testing of CPU command  Return for repair
62 System Fault on self test RAM  Return for repair
63 System Fault on self test ROM  Return for repair 
64 System Data error in internal Eeprom data  Return for repair 
65 System Data error in Eeprom about Alarm or info parameters (User)  Return for repair 
66 System Data error in Eeprom about Safe or Setup parameters (User)  Return for repair
67 System Data error in Eeprom in zone memory Return for repair  Return for repair 
68 System Fault runtime, unexpected interrupt  Return for repair 
69 System Fault runtime: fault in self testing sequence  Return for repair
70 Setup Last zone programming was unexpectedly broken off  Reprogam the unit / Return for repair 
 