How To Convert L7Z 1034 Parameter Files To The New 2032 Firmware Using CX-Drive If you try to connect CX-Drive with your saved parameters file taken from a 1034 firmware the following message will appear:
![]() Please follow the procedure below to convert the file into the new 2032 firmware.
1. With CX-Drive open the file where the parameter of L7 1034 or earlier firmware version are stored or upload the parameters for L7Z 1034 firmware. ![]() 4. Open Drive Type settings and select 2032 firmware number
![]() 5. Click OK, After that there can happen 2 cases :
1st case : Your original file had all parameters in its default value, in this case CX-Drive will automatically change 2032 and all the parameters will be in its default settings. No more actions you need to do in this case. 2nd case : Your original file has some parameter out of default, then the following message will be displayed ![]() Click Yes
6. The conversion process will start. The conversion rules applied by CX-Drive is: The parameters found under R2 rule will be shown in the following dialog, Click OK.
B1-03 (Stopping method selection) has been removed in the new version, as stopping methods other than "Ramp to Stop" makes no sense in a Lift application. O2-09 (Initialize Mode Selection) has dissappear, but it doesn't affect, as L7Z is European product. Now is fixed to European spec initialize. 7. The conversion is now completed. CX-Drive will have transfered all the parameters values to the new 2032 firmware. Link: |