I Would Like More Information About The Bend-Resistant Performance Of A Cable For The Robot Cable Connector "EE-1010-R".

A Robot Cable for the EE-1010-R has bending tolerance that is over three times higher than a common cable (electric cable) for the EE-1010.

Refer to the following results of the Cable Bending Destruction Test.

Cable Bending Destruction Test
  • Objective
    To evaluate the bend-resistant performance of a normal cable (electric wire) for the EE-1010 and a Robot Cable (electric wire) for the EE-1010-R.
  • Conclusion
    A Robot Cable (electric wire) for the EE-1010-R has bending tolerance that is over three times higher than a normal cable (electric wire) for the EE-1010.
    Robot Cable: Absolutely cut off by bending about 43000 times
    Normal Cable: Absolutely cut off by bending about 12000 times
  • Procedure
    As shown in the figure 1, reciprocating bending at an angle of 45 degrees is given at a rate of 55 times per minute with a load of 4.9N. This procedure should be repeated until a cable is absolutely cut off.
Cable Bending Destruction Test


Link:
http://www.myomron.com/index.php?action=kb&print=1007



Comments  

Translate: