Are Photomicro Sensors With The Light-ON/Dark-ON Selectable Operating Mode Available? Yes. The EE-SX67[] Series for Through-beam type (with slot), the EE-SY671/672 for Reflex type are available.
1. Photomicro Sensors "EE-SX67[]" (Channel type/Direct Current Optical Type)
Built-in models with 5 to 100mA direct switching capability
Light-ON⁄Dark-ON selectable operating mode (output configuration)
Response frequency as high as 1 kHz
Easy operation monitoring with bright light indicator
Wide operating voltage range from 5 to 24 VDC
Models (EE-SX[][][]A,[][][]R) with operation indicators that are lit when light is interrupted (when sensing objects are detected) are available.
![]() ![]() *1. The Dark-ON⁄Light-ON (selectable) models are normally used as dark-ON models. To use them as light-ON models, short-circuit the L terminal and positive (+) terminal. An EE-1001-1 Connector with the terminals already short-circuited is also available. Additionally, Connector "EE-1001", "EE-1009", Cable Connector "EE-1006", "EE-1010", and Robot Cable Connector "EE-1010-R" with the open terminals are available. *2. Model numbers ending in suffix A (e.g., EE-SX670A) indicate models for which the operation indicator will turn ON when the light is interrupted. *3. Model numbers ending in suffix R (e.g., EE-SX670R) indicate models for which the operation indicator will turn ON when the light is interrupted. 2. Photomicro Sensor "EE-SY671⁄672" (Diffuse Reflex ⁄Direct Current Optical Type) Models with sensitivity adjuster Easy adjustment with a built-in sensitivity adjuster Easy operation monitoring with bright light indicator Compact design with a special built-in IC makes it possible to directly switch currents up to 100mA. Wide operating voltage range from 5 to 24 VDC Smooth connection with Programmable Controllers as well as a variety of ICs and Relays is possible. ![]() ![]() The Dark-ON⁄Light-ON (selectable) models are normally used as dark-ON models. To use them as light-ON models, short-circuit the L terminal and positive (+) terminal. An EE-1001-1 Connector with the terminals already short-circuited is also available. Additionally, Connector "EE-1001", "EE-1009", Cable Connector "EE-1006", "EE-1010", and Robot Cable Connector "EE-1010-R" with the open terminals are available. Link: |
Comments | ||
|