Programmable Safety System


Articles
Bug Network Configurator for DeviceNet Safety
A bug in the Devicenet safety Configurator (version 2.00) makes it impossible to generate the report configuration during the necessary checks to lock the CPU, if the comments
Last Modified - 2009-10-29 - Similar Articles

How Many Safety Network Nodes Can I Attach To A Single NE1A Safety Network Controller (SNC) ?
The number of nodes is dependant upon the version of controller that is installed. 'V1' and above : 32 module connection, Pre 'V1' : 16 module connection. In larger
Last Modified - 2009-10-30 - Similar Articles

What Is The Program Capacity Of The NE1A Safety Network Controller?
V1 and above has a program capacity of 254 function blocks. Pre V1 has a capacity of 128 function blocks
Last Modified - 2009-10-30 - Similar Articles

How Does The NE1A Safety Network Controller (SNC) Work ?
The Safety network Controller NE1A has dual proccessors which constantly monitor each other. If any discrepancies are picked up between the two processors then the controller
Last Modified - 2009-10-30 - Similar Articles

How Does A Safety Network Work?
Each packet of information is sent twice and each packet is also time stamped. If the network does not see the packages within a certain time period or if the two packets dif
Last Modified - 2009-11-17 - Similar Articles

How Many Function Blocks Are Available On A Safety Network Controller?
This is dependant upon the model installed. Models 'V1' and above have 23 different types of Function block. Pre 'V1' models have 16 different types of Function block  
Last Modified - 2009-11-19 - Similar Articles

Does Ethernet Gateway Work With NE1A-L ? (standalone version)
Currently it is not possible to use with the standalone version
Last Modified - 2009-11-17 - Similar Articles

Are There Any Programming Limitations Using The Safety Network Controller?
There are limitations to bear in mind when programming the SNC and are as follows: - maximum 32 pages of program - 128 jump addresses - 128 text boxes -
Last Modified - 2009-11-17 - Similar Articles

How Long Can The I/O Cable Lengths Be?
The maximum cable length is 30 metres e.g. 30 metres to an E Stop switch and 30 metres back        
Last Modified - 2009-11-17 - Similar Articles

What Is The Maximum Cable Length I Can Achieve With My DeviceNet Safety Network?
Type The maximum lengths are 100m on thin cable and 500m on thick cable. Note: The maximum network speed is affected by the length of cables. The maximum speeds are: 500m
Last Modified - 2009-11-17 - Similar Articles

What Is The Current Rating Of The Safety Network Controller (NE1A) outputs?
The maximum current is 0.5A at 24vdc  
Last Modified - 2009-11-17 - Similar Articles

What Is Error 'p6' On The 7 Segment Display
One of the outputs will have a 24VDC signal on it which causes a total shut down of the controller - all the I/O indicators turn red and you can't connect to the unit. R
Last Modified - 2009-11-17 - Similar Articles

What Is The Baud Rate Of The NE1A Safety Network Controller?
The default setting is 125kbits/s
Last Modified - 2010-01-05 - Similar Articles

What Is The Maximum Number Of Safety Inputs And Outputs On A Normal Network?
The maximum number of safety IO on a normal network is 1000 inputs and 500 outputs
Last Modified - 2010-01-05 - Similar Articles

Does The Safety Network Controller SNC Require A Dedicated Ethernet Network For NE1A Units?
In theory a seperate network is not required, the DeviceNet safety will coexsist with exsisting Ethernet traffic. However as traffic increases on the network it will slow dow
Last Modified - 2010-01-05 - Similar Articles

Is It Possible To Program The NE1A And Make Program Alterations Over Ethernet IP?
No. It is only possible to monitor the program.
Last Modified - 2010-01-05 - Similar Articles

How Do You Configure The NE1A Safety Network Controller To Start In RUN Mode?
The user can select the NE1A-series Controller’s operating mode from the following two modes at startup, after the normal completion of configuration. The two Operating
Last Modified - 2014-03-13 - Similar Articles

Is It Possible To Bypass The Password On The NE1A Safety Network Controller?
If the NE1A is installed and a password set for access then it is not possible to bypass this user defined password if this password is not known. The reason is that once the
Last Modified - 2010-12-10 - Similar Articles


 