Articles
CX-Drive Is Causing Internal Error 16386
This issue is related to MDAC, and can be repaired/reinstalled by doing the following: To repair a copy of MDAC 2.8 on WinXP with SP2 installed first, locate the mdac.i
Last Modified - 2016-05-13 - Similar Articles

Profibus Configuration For Trajexia
Introduction Profibus communication between CJI-PRM21 and TJI-PRT This pdf document and lin
Last Modified - 2009-04-30 - Similar Articles

Will The MV Inverter Work?
The MV inverter needs at least firmware version 24 to work together with the PLC part. You can find out what version of firmware the inverter has with the digital-operator (
Last Modified - 2009-04-30 - Similar Articles

Why Do My Parameters Appear In Red Or With Empty Text Boxes And Why Can't I Edit Them? - CX-Motion version 1.0
There are several possible explanations for this. 1) The relevant database file is missing or corrupt, CX-MXX.mdb, where XX is the two letter language code below;
Last Modified - 2009-04-30 - Similar Articles

Why When A Parameter Set Is Opened Is A 'Low Resources' Warning Displayed? - CX-Motion version 1.0
When it is run or when a parameter set is opened CX-Motion checks to see if enough system resources are available. You will see one of these messages if system resources
Last Modified - 2009-04-30 - Similar Articles

Can I Install CX-Motion version 2.0 From Any User To Windows 2000 ?
It is only possible to install CX-Motion v2.0 from Administrator user.      
Last Modified - 2009-04-30 - Similar Articles

Can I Install CX-Motion version 2.10 To Windows XP Professional From Any Account ?
It is only possible to install CX-Motion v2.10 from an account with Administrator privileges.      
Last Modified - 2009-04-30 - Similar Articles

What Does The Error Message "The Database For CX-Motion Is Already Opened Exclusively" Mean?
This error message may occur by one of the following reasons: You have opened the CX-Motion database file with Access 97. --> Solution: Close the database file. Not
Last Modified - 2009-04-30 - Similar Articles

Can I Run CX-Motion From A Windows XP User With Limited Account Type ?
Limited account users of Windows XP Professional can not use CX-Motion unless they have read-write access granted to the program files. (This means, System Administrator has t
Last Modified - 2009-04-30 - Similar Articles

What Does "Installation Error: 1311. Source file not found: E:\Data1.cab." Mean? - CX-Drive
This is a Microsoft Windows security error that occurs when the Windows Installer running as the local system user is denied access to the .cab file. There are two ways to avo
Last Modified - 2009-04-30 - Similar Articles

Why Am I Prompted To Insert The Microsoft Office 2000 CD? - CX-Drive
When accessing areas within the CX-Drive the user is prompted to install a Microsoft Office feature by inserting the Microsoft Office CD. One area where this may arise is wi
Last Modified - 2009-04-30 - Similar Articles

What Is The Difference Between CS1W-NC[]13 Position Control Units And CS1W-MC221 Motion Control Units?
The differences between CS1W-NC[]13 and CS1W-MC221 are as follows: CS1W-NC[]13 Control target: Stepping Motor Drivers Servo Motors with pulse strings Direct Drive Mo
Last Modified - 2009-04-30 - Similar Articles

What's The Difference Between Cable R88A-CRWA010C And R88A-CRWA010C-DE?
Cables with option -DE should only be used for motors with Hypertac connectors. i.e motors SGMAH and SGMPH with D-option in the typename. OY in the typename indicates this i
Last Modified - 2008-11-08 - Similar Articles

I Need To Change My 3g3 1.1 KVA By CIMR-V7AZB0P40 ( Max Carrier Frequency Is 14.5kHz ) Needing Between 2.7A - 2.9A For Output Current. Should I Use A V7AZB0P70 Or Is V7AZB0P40 Enough ?
CIMR-V7AZB0P40 is rated 3.0A (200V Single Phase) at 10kHz Carrier Frequency. If you change the setting to 14kHz, the maximum allowed continous output current is 2,6A (87%
Last Modified - 2016-05-13 - Similar Articles

What Is The Difference Between The Inverters That Start With 3G3 And CIMR? Do They Work The Same?
The 3G3-type inverters are referred to as Omron brand, and the CIMR-type inverters are referred to as Double Brand, i.e Omron Yaskawa. They are basically compatible, both reg
Last Modified - 2008-11-08 - Similar Articles

I Am Unable To Set Max Frequency Higher Than 150 Hz In My F7 Inverter.
As default, F7-inverters are set for Heavy Duty (parameter C6-01 = 0) wich means that max frequency is limited to 150 Hz. If Normal Duty 1 or 2 is selected (C6-01=1 or 2) the
Last Modified - 2016-05-13 - Similar Articles

Would Like To Replace An 3G3EV Single Phase Inverter (0.75kW)? Does The Replacement Fit On The Filter We Are Using Today?
Replace with CIMR-J7AZB0P7 if you have no need for a braking resistor. If you need a braking resistor, use CIMR- V7ZB0P7. Both J7 and V7 fit on the same filter as 3G3EV. &n
Last Modified - 2016-05-13 - Similar Articles

What Do The Numbers In The IP-Rating Stand For?
IP Ratings explained (IPxx) IP stands for Ingress Protection IP (Ingress Protection) numbers are used to specify the environmental protection afforded by enclosures. These r
Last Modified - 2016-05-13 - Similar Articles

Where Can I Find Documentation?
You can access our one-stop library where you can download or print a wide range of useful product documentation (brochures, datasheets, instruction manuals, CAD drawings etc.
Last Modified - 2017-12-01 - Similar Articles

Where Can I Find Information Regarding CJ1W-CIF11?
Some information regarding RS232-C/RS422/RS485 converter CJ1W-CIF11 is embedded in manuals for CJ/CS/CP PLC-systems. There is also a datasheet included in the box at delivery
Last Modified - 2016-05-13 - Similar Articles

Startup Manual for V1000 in the HVAC application
Introduction Type introduction here Parameter setup: The following parameter list is the parameter values that must be configured/changed (highlighted), while the param
Last Modified - 2009-04-24 - Similar Articles

Getting Started With F7/E7
Introduction This tutorial is intended as a supplement to the original manuals for the products. Therefore, use this as a means to familiarise yourself wi
Last Modified - 2008-11-26 - Similar Articles

Getting Started With RV/PV
Introduction This tutorial is intended as a supplement to the original manuals for the products. Therefore, use this as a means to familiarise yourself wi
Last Modified - 2009-06-11 - Similar Articles

3G3MV As PID - An Example
Introduction This tutorial is intended as a supplement to the original manuals for the products. Therefore, use it familiarise yourself with the product, and n
Last Modified - 2008-11-19 - Similar Articles

Modbus PLC-MV/JV/PV
Introduction This tutorial is intended as a supplement to the original manuals for the products. Therefore, use it to familiarise yourself with the product but not as a guide
Last Modified - 2009-03-19 - Similar Articles

Why Do I Get A Dwell-Time Error With SYSMAC NCT?
Sysmac-NCT is a program for the configuration of the NC module. Settings for use in Windows 95/98/NT When trying to download parameters the NC module can have a long&nb
Last Modified - 2009-07-31 - Similar Articles

We Are Running A Three-Phase 200 VAC Induction Motor On Single-Phase 100 VAC. Are There Any Inverters With A Function That Boosts Voltage From 100 VAC To 200 VAC?
There are 3G3EV Inverters that can accept a single-phase 100 VAC input. These models have built-in circuit that boosts the voltage from 100 VAC to 200 VAC.    
Last Modified - 2009-01-20 - Similar Articles

Can One Inverter Be Used To Drive Multiple Motors?
Yes. Make the settings under the following condition: Inverter rated current ≥ Motor rated current × 1.1 (at continuous operation) Check whether the current is
Last Modified - 2009-01-20 - Similar Articles

Can A Single-Phase Motor Be Controlled By A 3G3EV Inverter With A Single-Phase 100-V Input?
No, a single-phase motor cannot be used. Doing so will cause a failure. The Inverter creates a virtual alternating current with high-speed switching. If the Inverter is co
Last Modified - 2009-01-20 - Similar Articles

I Want To Input The Multi-Step Speed Command In The Multi-Function Input Selection Parameter, But Err (error) Is Displayed And The Signal Can’t Be Input. What Is The Cause Of The Problem And The Solution?
Err (error) will be displayed and it won't be possible to input the signal if you attempt to input a setting that was already set with another Multi-function Input selector.
Last Modified - 2009-01-20 - Similar Articles

There Are Two Kinds Of Noise Filters Available As Inverter Accessories: The Input Noise Filter And Output Noise Filter. How Are These Filters Used?
The "Input" and "Output" means that these Inverter Noise Filters are connected to the Inverter's input side and output side. Input Noise Filter: Redu
Last Modified - 2009-01-20 - Similar Articles

I Changed The Set Value Of Inverter Parameter Number n01 To 9 (3-Wire Sequence), As Described In The Manual, But The Setting Changed To 1. Why Did It Change?
A setting of 9 causes the Inverter to be initialized in 3-wire sequence mode. When the setting is changed to 9 and the Return Key is pressed, the Inverter is immediately initi
Last Modified - 2009-01-20 - Similar Articles

I Am Moving An Inverter From A Location With A 50 Hz Power Supply Frequency To Another Location With A 60 Hz Power Supply Frequency. Are There Any Settings That Need To Be Changed?
One of the features of the Inverter is that it will control operation at the same speed regardless of the power supply frequency. The Inverter initially converts the input po
Last Modified - 2009-01-20 - Similar Articles

When I Want To Electrically Disconnect I/O, Is It Acceptable To Insert A Relay In The Inverter Input Power Supply Line?
From a safety standpoint in case of an internal inverter failure, install a circuit breaker or magnetic contactor in the Inverter's input power supply line, and install a circ
Last Modified - 2009-01-20 - Similar Articles

We Are Using An Inverter For Speed Control. How Can We Calculate The Rotational Speed Of An Induction Motor?
Generally, the speed (N) of an induction motor is expressed by the following formula: N = (120f/P) × (1 - S) (rpm) f: Primary frequency P: Number of motor poles
Last Modified - 2009-01-20 - Similar Articles

Are There Inverters With RS-422A/485 Communications?
Presently, the following models are capable of RS-422A/485 communications. 3G3MV Series 3G3RV Series 3G3JV Series Note:In the 3G3JV Series, a 3G3JV-PSI485J
Last Modified - 2009-01-20 - Similar Articles

Can An Inverter Be Operated And Stopped Using A Magnetic Contactor (MC)?
An Inverter can be operated and stopped by using a magnetic contactor (MC) on the primary side, but for the following reasons, do not turn the power supply ON and OFF frequent
Last Modified - 2009-01-21 - Similar Articles

Is It Necessary To Select An Inverter With A Capacity That Is One Class Higher Than The Capacity Of The Motor Being Used?
OMRON Inverters use an oversized power module that can output 200% of the motor's rated output, so it is not necessary to select an Inverter that is one class higher. On th
Last Modified - 2009-01-21 - Similar Articles

Is There A Servo System That Has Full-Closed Control?
Full-closed control is possible by installing a DeviceNet Communications Unit (R88A-NCW152-DRT) in an OMNUC W-series Servo Driver. A DeviceNet Communications Unit provides
Last Modified - 2009-01-21 - Similar Articles

Is There A Cable With Attached Connectors Available For The R88D-U Servo Driver's Analog Monitor Output?
Yes, there is a cable available. The Analog Monitor Cable for the W-series (R88D-W) Servo Drivers can be used. The Cable's model number is R88A-CMW001S.    
Last Modified - 2009-01-21 - Similar Articles

What Are The Differences Between The R88M-U[][][]30H Servomotor And Their Replacements, The R88M-U[][][]30HA Servomotor?
The R88M-U[][][]30H Servomotor's power supply cable outlet was bare, but the R88M-U[][][]30HA Servomotor's power supply cable outlet has a Servomotor cable clamp mounted in or
Last Modified - 2009-01-21 - Similar Articles

Can I Use An External Signal To Release The Brake Of A U-Series AC Servomotor Equipped With A Brake?
We recommend using the brake interlock signal. Open the connector case on the Servo side of the cable and add the brake interlock signal there. Often, a Programmable Con
Last Modified - 2009-01-21 - Similar Articles

What Is The Cause Of The E23 Error In An R88D-HT10 Servo Driver?
The 23 error occurs when there is an open phase in the main circuit. An error is detected when a low voltage was detected in the main circuit's input section and lasted longer
Last Modified - 2009-01-21 - Similar Articles

When A 3F88L-132 Cam Positioner Is Replaced With A 3F88L-160 Cam Positioner, Can The 3F88L-DP30 RPM Display Unit Be Used As-Is?
The Cam Output Cable, I/O Terminal, and Resolver can be used as-is, but the Display Unit cannot be used. The M7E and M7F Digital Display Units are available separately for us
Last Modified - 2009-01-21 - Similar Articles

What Should The Command Pulse Setting Be To Make A SMARTSTEP A-series Servo Driver Operate At 3000 r/min For The Various Resolutions?
Resolution Setting (Pins 4 and 5) Pin 5 Pin 4 Resolution setting OFF OFF 1,000 pulses/rotation (0.36°/step) OFF ON 10,000 pulses/rotation (0.036°/step) ON OFF 5
Last Modified - 2009-01-21 - Similar Articles

What Models Of Servomotors With Decelerators Are Used With SMARTSTEP A-Series Servo Drivers?
The Decelerator and Motor for the SMARTSTEP are separate devices. You must attach the Decelerator (sold separately) to a Servomotor with a straight shaft without a key. Not
Last Modified - 2009-01-21 - Similar Articles

V1000 Fuses

Last Modified - 2009-02-23 - Similar Articles

How To Convert L7Z 1034 Parameter Files To The New 2032 Firmware Using CX-Drive
If you try to connect CX-Drive with your saved parameters file taken from a 1034 firmware the following message will appear: Please follow the procedure below to convert th
Last Modified - 2009-05-06 - Similar Articles

MV-PLC Basic Positioning Sample
Introduction The PLC option board for 3G3MV inverters provides the needed hardware to perform a basic position control software. We can read an encoder with A and B phase sig
Last Modified - 2009-05-07 - Similar Articles

Error Codes For SIGMA II Firmware From Version 33 Onwards
Alarm Code Descriptions A.08 Linear scale pitch setting error. Implemented in firmware
Last Modified - 2009-05-21 - Similar Articles

Function Block For Position Controller -NCCPU031_MoveVelocity_DINT
Introduction The OMRON FB library for position controller provide a collection of Function Blocks developed for simple open loop axis positioning. Most of the FBs share the
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU062_Stop_DINT
Introduction The Omron FB library for position controllers provides a collection of Function Blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU021_MoveRelative_DINT
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open looop positioning. Most of the FBs share the sa
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU141_MoveTimeRelative_DINT
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU111_MoveInterrupt_DINT
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU051_Home_DINT
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU011_MoveAbsolute_DINT
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU131_MoveTimeAbsolute_DINT
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

Function Block Position Controller - _NCCPU120_MoveSequence
Introduction The OMRON FB library for position controllers provides a collection of function blocks developed for simple open loop axis positioning. Most of the FBs share th
Last Modified - 2009-05-28 - Similar Articles

How Can I Toggle The TJ1-FL02 Auxiliary Outputs?
DRIVE_STATUS AXIS(N) for reading the INPUTS Value (page 72 of the programming manual) DRIVE_CONTROL AXIS(N) for setting the OUTPUTS (page 69 of the programming manual)  
Last Modified - 2009-06-04 - Similar Articles

Circular CJ1M-V3 Function Block With NS-Smart Active Parts
Introduction This is a demo for a curve with two drive axles, the entries are made on a NS-user terminal with Smart Active Parts. The PLC program calculates a circle with g
Last Modified - 2009-06-11 - Similar Articles

Function Block For CJ1M For NC Modules
Introduction While there are pre-made function blocks in the FB library, they require rewriting of the CJ1M (EM-memory addressing is standard in FB, but not pr
Last Modified - 2009-06-11 - Similar Articles

An Example Program For A Conveyor Belt Using CJ1M-CPU22 Hardware
Introduction The parts are measured with an encoder, at the beginning of the conveyor belt by a sensor then in the distance with the sticky valve on. Interrupt input IN0 is
Last Modified - 2014-03-13 - Similar Articles

Example Of A Zero Origin Search Program For CQM1 Hardware
Introduction 1) 1. 1-axis configuration: The arrangement of the CW and CCW limit switch (limit signal left and right) and the near zero-limit switch for the 1-axis positio
Last Modified - 2009-06-11 - Similar Articles

Why Is CX-Drive Missing MX2 Inverter?
Symptom CX-Drive 1.9 does not show hardware option for MX2 inverter Affects CX-Drive 1.9 standalone users that updated with "CX-Drive Version update software 2009
Last Modified - 2009-09-21 - Similar Articles

Connecting NQ Terminal To MX2 Inverter
Introduction Below steps describe the connection of a NQ HMI terminal to a MX2 inverter. Hardware needed NQ3 or NQ5 ( Use COM1) MX2 inverter. Cable connection
Last Modified - 2011-07-05 - Similar Articles

Refresh-FB For Modbus Communication CJ/CS/CP1L To MV/RV/V7AZ/F7Z/E7Z/L7Z/V1000
Attached there is a smaller version of the function block from the library _INV002_Refresh.cxf It is for following inverter types: MV/RV/V7AZ/F7Z/E7Z/L7Z/V1000 The FB is&nbs
Last Modified - 2010-07-21 - Similar Articles

Modbus sample: Connecting NS To V1000
Introduction This sample is a demonstration for direct memobus connection between NS and V1000. For NS5 to NS12 models but must be with System Version later than version
Last Modified - 2010-05-05 - Similar Articles

How To Connect 3G3AX-MX2-ECT To TwinCAT
Introduction This article explains how to connect the 3G3AX-MX2-ECT drive with EtherCAT directly to a PC with TwinCAT installed. Following the instructions will allow yo
Last Modified - 2010-12-02 - Similar Articles

How To Connect R88D-KNxxx-ECT To TwinCAT
Introduction This article explains how to connect the R88D-KN drive with EtherCAT directly to a PC with TwinCAT installed. Following the instructions will allow you
Last Modified - 2010-12-02 - Similar Articles

Sample Structure For NCF71 Unit
Introduction CJ2 Family PLCs support Structure data types which can be used to access the data areas in SIO units like the NCF71 position control unit Using the structure T
Last Modified - 2011-05-31 - Similar Articles

Connecting NS Terminal To MX2 Inverter
 This article will describe how to connect a NS terminal directly to a MX2 inverter.   Hardware MX2 inverter; NS terminal; NS-AL002. Connection
Last Modified - 2011-08-30 - Similar Articles

Using CP1 Control For SmartStep2 Servos
This document describes the procedure to configure and connect a CP1L-M30 PLC to a SmartStep2 servo system for simple motion control. This example is intended for a new CP1/Sm
Last Modified - 2014-03-21 - Similar Articles

Using CP1 Control For MX2 Inverter Drives
This document describes the procedure to configure and connect a CP1L-M30 PLC to an MX2 inverter drive for simple motion control. This example is intended for a new CP1/MX2 us
Last Modified - 2014-03-21 - Similar Articles

How To Reset G5 ECT Error 40 "Absolute Encoder System Down" With Sysmac Studio
Introduction If a motor with an absolute encoder is used, the absolute value data in the absolute encoder is cleared when the Servo Drive is replaced, so needs to be setup&nb
Last Modified - 2012-04-16 - Similar Articles

Easy Positioning Function Blocks
Introduction This article provides a general overview of the attached Quick Start Guide for Easy Positioning Function Blocks. The Quick Start guide explains the criteria
Last Modified - 2025-02-19 - Similar Articles

Why Is My Velocity Trace Resolution Inaccurate In Sysmac Studio?
The Actual Velocity of a motion axis (like GX encoder or G5 servo) is not sent by the slave. It is calculated by the NJ Motion Control engine using the position counts between
Last Modified - 2013-05-23 - Similar Articles

How Do I Fix "NY Service State Disconnected" Error?
If you are running CX-Supervisor version 3.3 and receive "NY Service state disconnected" message in the error log when running on NY series IPC then it is likel
Last Modified - 2017-12-08 - Similar Articles


 