The contact ratings per pole are described below.
For example, for a 110-VAC or 24-VDC Relays are used with a resistive load, the contacts can switch 10 A, but if the load is inductive, a 110-VAC Relays can switch only 7.5 A, and a 24-VDC Relays, only 5 A (not 10 A).
LY4-series Contact Ratings (Check whether the specifications are suitable.)
| Type Load |
4 poles | |
| Resistive load | Inductive load (cos Φ = 0.4, L/R = 7 ms) |
|
| Contact Type | Single | |
| Contact material | AgCdO | |
| Rated load | 110 VAC 10 A 24 VDC 10 A |
110 VAC 7.5 A 24 VDC 5 A |
| Rated carry current | 10 A | |
| Maximum switching voltage | 250 VAC 125 VDC |
|
| Maximum switching current | 10 A | 10 A |