The Key Comes Out Of D4DL/D4BL Safety-Door Switches With A Mechanical Lock If I Insert The Key And Then Turn OFF The Solenoid. What Causes This And How Can I Correct It?


Cause: The release key is in the unlock position. The lock will not engage in the unlock position.

Countermeasure: Set the release key to the lock position.
 
 