I Need To Change My 3g3 1.1 KVA By CIMR-V7AZB0P40 ( Max Carrier Frequency Is 14.5kHz ) Needing Between 2.7A - 2.9A For Output Current. Should I Use A V7AZB0P70 Or Is V7AZB0P40 Enough ?


CIMR-V7AZB0P40 is rated 3.0A (200V Single Phase) at 10kHz Carrier Frequency.

If you change the setting to 14kHz, the maximum allowed continous output current is 2,6A (87% derating). So if your actual continous output current is between 2.7A-2.9A, we recommend using CIMR-V7AZB0P70.
 