Fn04 Read Input Register (Modbus / TCP) |
Name | Fn04_ReadInputRegister: Fn04 Read Input Register (Modbus / TCP) |
Basic Function | Request for Read One Input Register | ||
Symbol | |||
Originates from | Tsunagi Lab Europe | ||
Created by | OEE-HQ HvB (creation and testing) | ||
File Name | Fn04_ReadInputRegister.cxf | ||
Applicable models | CPU Unit | CP1L-EL or CP1L-EM | |
CX-Programmer | Version 9.40 or higher | ||
Conditions for usage | The following specifications can be used for FB Auto Allocation: - CIO 0000 to 6143 - HR H000 to H511 - AR A448 to A959 - D00000 to D09999 for the CP1L-EL - D00000 to D32767 for the CP1L-EM |
||
Function Description | Fn04_ReadInputRegister Function Block read one Input Register conform the address variable and Outputs the result in the data variable Output. | ||
Kind of FB definition | Connect Always ON type Connect the EN input to the Always ON Flag (P_ON). The same instance cannot be used in two or more places. |
||
FB Precautions |
Omron can not be held responsible in case of malfunction. |
||
EN input condition | • Connect EN to condition for the FB to Work • Fn04 send the Request for Read the Input Address • Socket Number 1 to 3 • Register Address |
||
Restrictions Input variables |
• Socket Number 1 to 3 | ||
Output variables | • This FB requires multiple cycles to process. • The status of the Outputs bits are Reset if the Fn04 bit is OFF. Except for the Data Output. |
||
Application example | Fn04_ReadInputRegister Function Block is designed for use with the other Function Blocks. For more more details on the use of this function block see also CP1L-EL/EM Modbus TCP Client Socket Services. The Socket Number Output can be used for the Socket Number Input used by: - Open_Socket Example: |
||
Related manuals | CP1L-EM/EL CPU Unit Manual (W516-E1) |
-
Variable Table
Input Variables
Name | Variable name | Data type | Default | Range | Description |
---|---|---|---|---|---|
EN | EN | BOOL | 1 (ON): Starts FB 0 (OFF): Does not start FB |
||
Read Input Register | Fn04 | BOOL | Start request for Read Input Register | ||
Socket Number | SocketNo | UNIT | &1 to &3 | &1 to &3 | |
Address | Address | WORD | Register address to read |
Output Variables
Name | Variable name | Data type | Range | Description |
---|---|---|---|---|
ENO | ENO | BOOL | 1 (ON): FB operating normally 0 (OFF): FB not operating normally |
|
Done | Done | BOOL | Done | |
Error | Error | BOOL | Error | |
Error ID | ErrorID | UNIT | Error code: TCP/UDP Error Codes Ethernet Units Construction of Networks Operation Manual (W420) 7-3 Command/Response Reference FINS Error Codes Communications Commands Reference Manual (W342) 5-1-3 Error Codes CP1L-EL/EM CPU Unit Operation Manual (W516) 12-1 Troubleshooting |
|
Data | Data | WORD | Contents of register |
Revision History
Version | Date | Contents |
---|---|---|
1.00 | 21-Apr-2012 | Original production |
Note