What Is The Maximum Capacity Of Online Edit?


The maximum capacity of online edit, in terms of steps program / editable word, depends on the type of PLC and the size of the frame data.
 
Series CJ / CS
Steps = (Fins frame length -16) / 4
Max = 256

Series C
128-word sets

CV Series
Words = (Fins frame length -16) / 4

Summary
PLC Protocol Frame Size Max.
CS Toolbus 1004 247
SYSWAY 540 131
CLK 2000 256
Ethernet 2000 256
CV Toolbus 542 263
SYSWAY 542 263
CLK 2002 993
Ethernet 2002 967

 

 