Why Is CX-Simulator Disabled In CX-Programmer Menu?


On some machine installations it is possible for the linkage between CX-Programmer and CX-Simulator to be broken. The CX-Simulator menus become disabled and 'greyed' out:
 
This can be caused by third party Registry Cleaning software (like CCleaner or Norton Security) which has deleted some required settings. This problem can be resolved by re-adding the required registry settings by downloading and double clicking the attached file. If the problem persists, then disable any Registry cleaners or security software
 

Note: This REG file assumes installation to the default English path for KICKENGINE.EXE (normally C:\Program Files\Omron\CX-Server).  You may need to open the REG file in Notepad and edit it first in any of these conditions:
- KICKENGINE.EXE is not present in folder C:\Program Files\Omron\CX-Server
- You are running on a non-English Operating System
- You have installed CX-One to a custom drive or path
- You have previously installed CX-Simulator as a standalone product
- You have upgraded from an old version of CX-One, keeping older path settings

 

 



Attachments



Comments (View All Comments / Add Comment)

Related Articles
How To Convert CX-Designer Projects Version 8.2 To 8.1
Here is a description on how to convert the system version of projects from Version 8.2 to Version 8.1 with the CX-Designer. This is helpful if you want to use your...
How Do I Address Extended Memory Banks In PLCs From Visualisation Software?
Introduction Extended memory is available on many PLCs. Omron visualisation software is able to address this memory using a special syntax to refer to the correct memory...
Transfer Compact Flash memory card
Introduction This tutorial is designed to explain the transfer process of compact flash memory cards for CS1/CJ1 PLCs.   Saving configuration files /...
 
Created 2009-02-16
Modified 2010-03-11
Views 981

 

You are not logged in.